Specifications
Oneshot mode
Sample, Average, Peak, Interlaced peak, High Resolution modes
 
Multishot mode

Sample, Average, High resolution,Peak, Interlaced Peak modes.

Averages: 2,4,8,16,32,64,128,256.

Peak collecting cycles: 2,4,8,16,32,64,128,256.

 
Input
Input resistance
1MΩ±1%
Input capacitance (20...200 mV/div)
15±5 pF
Input capacitance (0,5...10 V/div)
25±5 pF
Input voltage
±100 V
Maximum input voltage
±250 V (DC+peak AC)

 
Vertical characteristics
Bandwidth (by -3dB level) 15 MHz
Rise time <25 ns
Overshoot <5%
Volt/div positions
9
Volts/Div setting min
20 mV
Volts/Div setting max 10 V
closed and grounded input (AC/ AC+DC)
+
Low-pas filter bandwidth
3 MHz
Vertical position range (ex 10V/div) ±12 div
Vertical position range (only 10V/div) ±6 div
Offset step
1/32 div
Vertical accuracy ±5%

 

 

 

 
Sensitivity, Input voltages, resolution, offset
Sensitivity input resolution with offset
2 mV/div ±320mV 0,6mV 5 bit 7 bit
4 mV/div ±320mV 0,6mV 6 bit 8 bit
10 mV/div ±320mV 0,6mV 7 bit 9 bit
20 mV/div ±320mV 0,6mV 8 bit 10 bit
50 mV/div ±800mV 1,6mV 8 bit 10 bit
100 mV/div ±1,6V 3,1mV 8 bit 10 bit
200 mV/div ±3,2V 6,2mV 8 bit 10 bit
500 mV/div ±8V 15mV 8 bit 10 bit
1 V/div ±16V 31mV 8 bit 10 bit
2 V/div ±32V 62mV 8 bit 10 bit
5 V/div ±64V 150mV 8 bit 10 bit
10 V/div ±120V 310mV 8 bit 9.6 bit

 

 

 
ADC characteristics
resolution 8 bit
maximum sampling rate 32MS/s
maximum sampling rate (overclock)
60MS/s
Differential nonlinearity 0.2 LSB
Input Bandwidth (–3 dB) 300 MHz
Signal-to-Noise and Distortion (f = 16 MHz)
48 dB
Total Harmonic Distortion (f = 16 MHz)
-58 dB
maximum sample rate setup step 50 kHz
sample rate setup accuracy 1 %
sample rate measure accuracy
0,1 %
maximum sampling rate at equivalent time sampling (RIS)
800 MS/s

Averaging of 128 or 256 acquisitions effectively increases vertical resolution to 11 bits and vertical sensitivity to 2 mV/div (for signals containing sufficient noise component)

 
Realtime sampling

режимы запуска развертки :   автоматический, ждущий, ручной

Roll mode: at sweep speeds of 200 ms/div and slower

 

Single-shot acquisition modes:

slower 2us/div Normal, Peak Detect, Average, High Resolution
slower 1us/div Normal, Average
0,5 and 1us/div Normal

Record length:

faster 10us/div 250 points
10us/div and slower, Normal, Half-Peak Detect, Average 1792 points
10us/div and slower, Peak Detect, High Resolutions
896 points

 

Multi-shot acquisition modes: Normal, Peak Detect, Average, High Resolution.

Number of averages selectable at: 2, 4, 8, 16, 32, 64, 128, 256

Record length:

faster 10us/div 250 points
10us/div and slower, Average 597 points
10us/div and slower, Half-Peak Detect 896 points
10us/div and slower, Peak Detect, High Resolutions 448 points

 

 

 

 
stroboscope (RIS) sampling

run mode: manual, norm

sampling: sample,average, peak, high resolution

equivalent sample rate 800 Ms/s
max sample rate frequency setup step 800 kHz
sample rate setup accuracy <1%
sample rate measurment accuracy <0,1%
max averages / peak collecting cycles 255

 

 

 
Trigger modes

Auto, Normal.

Single cycle mode, Continuous run.

Programmed wait time.

Programmed Delay.

 
trigger characteristics

Slope rise,fall,rise+fall
trigger level range all 8 div
trigger level setup accuracy div / 32
trigger bandwidth
0...5 MHz
DC to 1MHz trigger sensitivity <0.2 div
1 MHz to 5MHz trigger sensitivity <0.5 div
trigger hysteresis stages 16
trigger HF filters 4
pre-trigger 0...100%
post-trigger 0...100%
max trigger delay 1000 s
trigger delay setup accuracy 120 ns
max trigger wait time (norm mode) 1000 s
max trigger wait time (auto mode) 1000 s